Roland SERVICE INFORMATION NO 100217-1 JP-6 SUBJECT JP-6/TR-808 (CR-5000/8000) ARPEGGIO CONNECTION This information is our final solution to a misoperation on JP- 6/TR-808 (CR-5000/8000) arpeggio connection which sometimes some steps are missed, especially, in the range from middle to high tempo. And the following procedure should take priority of both Service Information No.100208-2 and 100203. Please refer to them. To ensure the JP-6/TR-808 arpeggio connection, we changed program version of PROM 2732A-A from ver. 2 to ver. 3, and the modified new PROM (ver. 3) has already been used in JP-6 from the serial number 755800. In case that you have to do the same in the above purpose, it needs for you to pay attention to the following points. 1) JP-6 with the serial numbers from 250100 to 260449 STEP-1 : Replace PROM 2732A-A (ver. 1 or 2) with new one (ver. 3). STEP-2 : Check whether C-17 capacitor on JACK BOARD is 0.001 type or not. If so, it is ok. STEP-3 : Cut the light brown wire (BJ-7) of the connector mounted on BENDER BOARD so that a circuit (TR-3, R-20 and R-23) in the BENDER BOARD may not function. Please refer to the enclosed drawing. NOTE: This circuit has been removed from the BENDER BOARD already from the serial number 260450. 2) JP-6 with the serial numbers from 260450 to 353799 STEP-1 : Replace PROM 2732A-A (ver. 2) with new one (ver. 3). STEP-2 : Check whether C-17 capacitor on JACK BOARD is 0.001 type or not. In case of that it is 0.1 type, exchange it for 0.001 type. 3) How to see the program version of PROM 2732A-A See file "100217_draw_c" DRAWING Black disk marks indicate A program version.